48FCFM16A3A5-0A0A0. 48FC = Gas Heat Packaged Rooftop. F = High Heat. M = Single Circuit, Two Stage Cooling Model. 16 = 15 Tons. A = No Smoke or CO 2 sensor. 3 = Direct Drive, Eco Blue, High Static Option. A = Al/Cu - Al/Cu. 5 = 208/230-3-60.20 to 60 Nominal Tons. 48A2 – CV/SAV, Vertical. 48A3 - VAV, Vertical. 48A4 – CV/SAV, Horizontal. 48A5 - VAV, Horizontal. Carrier A Series Rooftop products are pre-wired and charged with refrigerant and tested in both cooling and heating modes at the factory. All models feature an industrial grade cabinet with fully hinged access panels.Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: Single cooling stage models are available from 3 -- 10 ton. Two cooling stage models are available from 7.5 -- 15 ton. SEER up to 13.0. (up to 13.4 with ECM motor) EER's up to 11.1. (up to 11.4 with ECM motor)View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) … ASHRAE 90.1 compliant. Up to 13.0 SEER, 11.8 IEER, and 11.1 EER. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 25°F (-4°C) using winter start kit. Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain.

10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48fc-8-14-01si ; 48fcem 10t 208-230-3 ... Specifications. Brand ...

Carrier West Training – HVAC TrainingReplacement for. 48TCED08A2A6-0A0G0 - Gas Heat/Electric Cool Rooftop, 2-Stg 7.5T 460-3-60 Medium Fan; 48TCEM08A2A6-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU

Carrier Puerto Rico - Air ConditioningView and Download Carrier 48FC Series controls, start-up, operation and troubleshooting online. Single Package Rooftop Units with SystemVu Controls Version 1.X and Puronr (R-410A) Refrigerant. 48FC Series air … 48TCED08A2A5-0A0G0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU; 48TCEM08A2A5-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU 48FC-4-7-02SB. 48FC 04-07 WEATHERMAKER® SERIES WITH ECOBLUETM TECHNOLOGY SINGLE PACKAGE ROOFTOP GAS HEAT/ELECTRIC COOLING …GAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and …

CE - Carrier Enterprise

Electric heating and electric cooling with up to 15.5 SEER2 for enhanced energy savings with enhanced comfort features. 4.5 out of 5 stars. 4.5 out of 5 stars. 4.5 out of 5 stars. 81 Reviews. 5 Star. 65% . 4 Star. 21% . 3 Star. 9% . ... Your Carrier expert will recommend the appropriate model to fit your needs. Warranty. 10-year parts limited ...

Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES . Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor)We would like to show you a description here but the site won’t allow us.Build performance, reliability and flexibility into your custom air handler solution. Carrier’s Aero® air handlers provide advanced technology and custom features in streamlined, easy-to-install packages. Indoor and outdoor air handling units are available to handle a wide variety of applications. 5 Product (s)Replacement for. 48KCEA06A2A5-0A0A0 - 5.0T G/E RTU PURON 208/230-3 MED FAN; 48TJE006---5--GA - 5.0T G/E RTU 3PH STD HEAT W/ALT MTR; 48FCEA06A2A5-0A0A0 - 5 TON Medium Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTUWhen it comes to selecting a fifth wheel, there are many factors to consider. With so many different models and features available, it can be difficult to decide which one is right...

Carrier Weather Series Rooftop Units* with EcoBlue ... 48/50FC – 3 to 5 Ton Models 48/50FC – 6 Ton Models 48/50GC – 3 to 5 Ton Models. Created Date: 1/22/2020 5:00:47 PM ...10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; Availability Available ...View and Download Carrier 48HC*04–14 service and maintenance instructions online. Nominal 3 to 12.5 Tons With Puron (R410A) Refrigerant. 48HC*04–14 air conditioner pdf manual download. ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge ...Carrier48FCEA06A3A5-0A0A0 - 5 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT ... Share. Description. 48FCEA06A2A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models 06 = 5 Tons A = No Smoke or CO 2 sensor 2 ... Brand Carrier; Equipment Type Commercial Packaged … Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas Heat Revit 1 is BIM (Building Information Modeling) software, developed by Autodesk 2. It allows you to design with both parametric 3D modeling and 2D drafting elements. Building Information Modeling is a Computer Aided Design (CAD) paradigm that employs intelligent 3D objects to represent real physical building components such as walls and doors.

NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Variable speed cooling capacity control on all models. SEER to 20.0. Gas efficiencies up to 81%. Cooling operating range up to 125 °F (52°C) and down to 0°F (-18°C) 6 TON High Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A2A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...

3 to 12.5 Nominal Tons. Exclusive, new EcoBlue™ Technology was designed to improve performance and efficiency while decreasing maintenance and installation costs. The … Page 41: Rtu Open Controller (Factory Option) Completing Return Air Smoke Sensor Installation RTU Open Controller (Factory Option) Unscrew the two screws holding the Return Air Smoke For details on operating 48FC**04-07 units equipped with the Detector assembly. See Fig. 53, Step 1. With solutions from 10 through 500 tons, screw or scroll, Carrier air-cooled chillers are the best choice for your needs. With a wide range of air-cooled chiller scroll and screw types, capacities (10 to 500 tons) and sustainable refrigerant options, Carrier is a leader in the industry. Whether it be non-ozone depleting refrigerant, simple ...CE - carrierenterprise.comOverview. The Comfort series of air conditioners is designed to give you simple, efficient, affordable cooling. And with impressive SEER ratings they can still make you smile when it comes time to pay your energy bill. California residents please see Proposition 65.Restore set-points for thermostat and humidistat (Y/N) _____. 2021 Carrier. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs …View and Download Carrier 48FC Series controls, start-up, operation and troubleshooting online. Single Package Rooftop Units with SystemVu Controls Version 1.X and Puronr (R-410A) Refrigerant. 48FC Series air conditioner pdf manual download. Also for: 50gc series, 48fc 04, 48fc 05,...View and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge …

6 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...

Carrier provides a full line of packaged rooftop equipment to meet demanding HVAC systems requirements, from small electric cooling units to large gas heat/electric cooling units like the WeatherExpert® series, which has the industry’s highest part-load performance IEER ratings in the 3-5 ton range. Carrier DOAS (Dedicated Outdoor Air Systems) are …

els are in addition to the 3 to 5 ton models with SEERs up to 17.5 and 12.5 to 23 ton models with IEERs up to 19.1 to provide a full range offering. Ultra high efficiency With IEERs up to 20.8, these new WeatherExpert models help to contrib-ute in LEED credits and help qualify for rebates. The high IEER efficiencies areCE - carrierenterprise.comRevit 1 is BIM (Building Information Modeling) software, developed by Autodesk 2. It allows you to design with both parametric 3D modeling and 2D drafting elements. Building Information Modeling is a Computer Aided Design (CAD) paradigm that employs intelligent 3D objects to represent real physical building components such as walls and doors.48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... 48FCFM07A1A5-0A0A0 - 6 TON High Gas Heat 14 SEER Standard EFFICIENCY Standard STATIC 208/230 ... 48fcfm07a3a5-0a0a0_submittal; Specifications. Brand Carrier; Availability Available for Delivery; Warehouse Availability AVON, MALD; BTU Input …7.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM08A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 08 = 7.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …6 2 15.0 74 x 47 x 41 67 110 150 607 Gas Heating / Electric Cooling Models – 48FC Electric Heat / Electric Cooling & Cooling Only Models – 50FC Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) IEER Dimensions (in) L x W x H Electrical Heat Nominal kW Range Approx. Unit Weight (lbs) 3 1 (14.0) 74 x 47 x 33 4.0 to 15.0 437AERO® Indoor/Outdoor Small Air Handler. 39S. Construction: Compact single/double-wall. Application: Indoor, Outdoor. Airflow Range (Cfm): 400 - 8,500. Documents Details. Carrier offers custom, compact, single wall and double wall air handlers and air handling units to meet the HVAC needs of commercial customers.6 2 15.0 74 x 47 x 41 67 110 150 607 Gas Heating / Electric Cooling Models – 48FC Electric Heat / Electric Cooling & Cooling Only Models – 50FC Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) IEER Dimensions (in) L x W x H Electrical Heat Nominal kW Range Approx. Unit Weight (lbs) 3 1 (14.0) 74 x 47 x 33 4.0 to 15.0 437 CE - carrierenterprise.com 48ES, 48VL, 48XL Small Packaged Products Air Conditioner / Gas Furnace Family REVIT Files. 48XZ, 48VT, 48XT Small Packaged Products Air Conditioner / Hybrid Heat Family REVIT Files. 50ES, 50VL, 50XL Small Packaged Products Air Conditioner Family REVIT Files. 50EZ, 50VT, 50XT Small Packaged Products Heat Pump Family REVIT Files. Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector Accessory. Brand: Carrier | Category: Air Conditioner | Size: 0.33 MB. Carrier 48FC Series Pdf User Manuals. View online or download Carrier 48FC Series Installation Instructions.

20 to 60 Nominal Tons. 48A2 – CV/SAV, Vertical. 48A3 - VAV, Vertical. 48A4 – CV/SAV, Horizontal. 48A5 - VAV, Horizontal. Carrier A Series Rooftop products are pre-wired and charged with refrigerant and tested in both cooling and heating modes at the factory. All models feature an industrial grade cabinet with fully hinged access panels.The price for a ton of coal varies greatly depending on what kind of coal it is. According to the U.S. Energy Information Administration, the average price for coal in 2012 was $39...Replacement for. 48TCED08A2A6-0A0G0 - Gas Heat/Electric Cool Rooftop, 2-Stg 7.5T 460-3-60 Medium Fan; 48TCEM08A2A6-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTUAre you in the market for a half ton towable fifth wheel? If so, you’re in luck. There are plenty of great options out there to choose from. But with so many different models and f...Instagram:https://instagram. la forum seating chartla cantera mexican restaurantmexican restaurants cedar lakeavgo earnings whisper 7.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM08A3A6-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 08 = 7.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability … cheapest gas in kenosha wiclermont county court access Has your 1.5-ton air conditioner been underperforming lately? Are you experiencing reduced cooling efficiency or warm air blowing out of your AC vents? These are common signs that ... mount vernon patch S Two cooling stage models are available from 7.5 -- 15 ton. S SEER up to 13.0. S EER’s up to 11.1. S IEER’s up to 11.8. S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. S Utility connections are the same because 3 -- 12.5 ton units fit on existing Carrier rooftop curbs. This saves time andCarrier roof curbs that were installed back to 1989, which makes replace-ment easy and eliminates the need for curb adapters or changing utility connections. Single-stage units deliver SEERs up to 14.3. IEERs up to 15.0 and heating HSPFs up to 8.2. All models are capable of either vertical or horizontal airflow.